ascot diagnostics

A7731

Warning: {value} doesn’t match the pattern of {what}

A constant is assigned, passed or returned where the declared type has a PATTERN it does not match, like "12" for %String(PATTERN = "3N"). The constant may also be a property’s InitialExpression or a formal argument’s default value. IRIS checks a property’s pattern only when the object is validated or saved, and a mismatch then fails with ERROR #7209. It never checks a formal argument or a return value. Match the pattern, or change it where the type is declared.

IRIS compiles the example.

Class Demo.PatternMismatch Extends %RegisteredObject
{

Property Code As %String(PATTERN = "3N") [ InitialExpression = "1" ]; //! A7731

ClassMethod Take(code As %String(PATTERN = "3N")) As %String
{
    Return code
}

ClassMethod Call() As %String
{
    Set me = ..%New()
    Set me.Code = "12" //! A7731
    Return ..Take("abc") //! A7731
}

}

All diagnostics