ascot diagnostics

A9360

Information: Cannot confirm ‘{mem}’ exists on {on}{cls}: its hierarchy includes {unseen}

The class or one of its superclasses is one ascot cannot read, and no class ascot can read declares the member. That class is neither in the workspace nor on the IRIS instance, or its workspace file does not parse. It may declare the member, which ascot therefore takes as present and untyped. Open that class’s file in the workspace, or check against an IRIS instance (--iris). Without an IRIS instance (--iris none), every system superclass is such a class, and the Extends naming it is A8061.

IRIS compiles the example. Checked without an environment, as --iris none.

Class Demo.UnconfirmedMember Extends %Persistent //! A8061
{

Method Store() As %Status //! A8061
{
    Quit ..%Save() //! A9360
}

}

All diagnostics